Managing Faults 55
set
/SYS/PSx/prepare_to_remove_acti
on true
removefru PS0|PS1 Indicates if it is okay to perform a
hot-swap of a power supply. This
command does not perform any
action. But this command provides
a warning if the power supply
should not be removed because the
other power supply is not enabled.
reset /SYS reset [-y] [-c]
-y enables you to skip the
confirmation question.
-c executes a console command
after completion of the reset
command.
Generates a hardware reset on the
host server.
reset /SP resetsc [-y]
-y enables you to skip the
confirmation question.
Reboots the service processor.
set /SYS/keyswitch_state
value
normal | stby | diag |
locked
setkeyswitch [-y] value
normal | stby | diag | locked
-y enables you to skip the
confirmation question when
setting the keyswitch to stby.
Sets the virtual keyswitch.
set /SUS/LOCATE value=value
[Fast_blink | Off]
setlocator value
[on | off]
Turns the Locator LED on the server
on or off.
(No ILOM equivalent.) showenvironment Displays the environmental status
of the host server. This information
includes system temperatures,
power supply, front panel LED,
hard drive, fan, voltage, and current
sensor status. See “Display
Individual Component Information
With the ILOM show Command”
on page 25.
show faulty showfaults [-v] Displays current system faults. See
“Detecting Faults” on page 30.
TABLE: Service-Related Commands (Continued)
ILOM Command ALOM CMT Command Description
Seitenansicht 80