Managing Faults 53
Note In the ILOM shell there is no notification when the system is actually
powered off. Powering off takes about a minute. Use the show /HOST command to
determine if the host has powered off.
ILOM-to-ALOM CMT Command
Reference
TABLE: ALOM CMT Parameters and POST Modes on page 56 describes the typical
commands for servicing a server. For descriptions of all ALOM CMT commands,
issue the help command or refer to the following documents:
Integrated Lights Out Manager 3.0 Concepts Guide
Integrated Lights Out Manager 3.0 Supplement for SPARC Enterprise T5440 Server
TABLE: Service-Related Commands
ILOM Command ALOM CMT Command Description
help [command] help [command] Displays a list of all available
commands with syntax and
descriptions. Specifying a command
name as an option displays help for
that command.
set /HOST/send_break_action
true
break [-y][-c][-D]
-y skips the confirmation
question.
-c executes a console command
after the break command
completes.
-D forces a core dump of the
Solaris OS.
Takes the host server from the OS to
either kmdb or OpenBoot PROM
(equivalent to a Stop-A), depending
on the mode Solaris software was
booted.
set
/SYS/component/clear_fault_a
ction true
clearfault UUID Manually clears host-detected
faults. The UUID is the unique fault
ID of the fault to be cleared.
start /SP/console console [-f]
-f forces the console to have read
and write capabilities.
Connects you to the host system.
Seitenansicht 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 213 214

Kommentare zu diesen Handbüchern