136 SPARC Enterprise T5440 Server Service Manual July 2009
“Remove a Fan Tray” on page 83
Note You must remove all four fan trays.
“Remove the Fan Tray Carriage” on page 129
1. Remove the CMP/memory module bracket.
The bracket is secured with six captive No. 2 Phillips screws. See FIGURE:
CMP/Memory Module Bracket Captive Screw Locations on page 136.
FIGURE: CMP/Memory Module Bracket Captive Screw Locations
2. Remove the flex cable retainer.
Loosen the captive No.2 Phillips screw and lift the retainer up and out of the
chassis.
3. Unplug the flex cable from J9801 on the motherboard.
4. Unplug the auxiliary power cable from J9803 on the motherboard.