Managing Faults 27
Related Information
■ “Diagnostic Flowchart” on page 11
■ “Change POST Parameters” on page 28
■ “Run POST in Maximum Mode” on page 28
■ “Detecting Faults Using POST” on page 42
■ “Clear Faults Detected During POST” on page 48
■ SPARC Enterprise T5440 Server Installation and Setup Guide
■ SPARC Enterprise T5440 Server Administration Guide
▼ Change POST Parameters
1. Access the ILOM prompt.
See “Connecting to the Service Processor” on page 22.
diag_trigger none Does not run POST on reset.
user_reset Runs POST upon user initiated resets.
power_on_reset Only runs POST for the first power on. This
option is the default.
error_reset Runs POST if fatal errors are detected.
all_resets Runs POST after any reset.
diag_verbosity none No POST output is displayed.
min POST output displays functional tests with a
banner and pinwheel.
normal POST output displays all test and informational
messages.
max POST displays all test, informational, and some
debugging messages.
TABLE: ILOM Parameters Used for POST Configuration (Continued)
Parameter Values Description