CHAPTER 2 DEPENDENCE FUNCTIONS
2.3.4.7 Performance-Buffer-Full Break
It is a function to abort the program execution when the buffer for the performance
measurement data storage becomes full.
Performance-Buffer-Full Break
It is a function to abort the program execution when the buffer for the performance measurement data storage
becomes full.
When a break occurs due to a performance-buffer-full break, the following message is displayed on the
Status Bar.
Break at Address by performance buffer full
Setting Method
The performance-buffer-full break is controlled by the following method.
Command
- SET PERFORMANCE/BREAK
Refer to "4.7 SET PERFORMANCE (type 1)" in "SOFTUNE Workbench Command Reference
Manual".
Dialog
- Performance set dialog
Refer to "4.4.13 Performance" in "SOFTUNE Workbench Operation Manual".